NoDec® WIZARD RH

NoDec® WIZARD RH

3 Cell-Cycle Alternating Zero Pressure Air Mattress Replacement System with Lateral Rotation Functions

NoDec® WIZARD is a unique 3 cell-cycle ‘zero pressure’ dynamic support surface that provides both pressure injury prevention and reduces the risk of infective chest complications in completely immobile patients. The mattress design of NoDec® WIZARD is based upon unique V-shaped air-cells which provide complete pressure elimination.

The NoDec® WIZARD offers three different ‘therapy methods’ in one system – a 3 cell-cycle alternating zero pressure air-mattress, a lateral rotation mattress and a combined 3 cell-cycle alternating zero pressure cycle air mattress with lateral rotation functions.

The tilt function provides lateral rotation therapy on either a continuous or a programmed 6 hour basis. The slow and controlled tilt transfers body support laterally changing contact points, as well as assisting with pulmonary functions and reducing manual handling. The mattress also uses solenoid valves to increase airflow efficiency in and out of the cells, whilst vacuum assisted deflation quickly reduces interface pressure over the off-loaded cells to create a reactive hyperaemic response in the deep tissues surrounding the bony prominences.

The NoDec® WIZARD mattress has 20 arrow shaped air-cells placed transversely with two reinforced, permanently inflated cells running lengthwise at the edges to protect against patient falls and assist when transferring from bed. Selecting a lateral rotation program gently inclines the patient left or right and the permanently inflated cells act as protective bolsters keeping the patient away from the mattress edges.

Clinically Proven Therapy

V-shaped air-cells are retained in place beneath the body so that contact pressure is removed from exactly the same site that it had been applied
Continuous lateral rotation therapy is provided by deflating the outside portion of the base segment of the V-shaped cells
Touch screen display enables selection of lateral rotation frequency
3 cell-cycle system with 50% more support cells makes it easier for deflating cells to retract away from body contact and achieve zero interface pressure
Vacuum assisted air-cell deflation ensures complete evacuation of air from deflating cells

Patient Safety and Comfort

Touch screen display enables one touch program selection for both pressure area management and lateral rotation therapy
Ergonomic patient management unit with touch screen, automatically adjusts cell pressures to patient weight and changes in body position
Comfort control with three pressure settings allows adjustment to suit individual patient comfort or clinical requirement
In the event of a power failure, the mattress remains inflated for at least 6-8 hours depending on the weight of a patient
Permanently inflated side formers provide a firm mattress edge to ensure patient safety and support during bed exits or transfers to trolley or chair

Additional Nursing Support

Impressive tilt facility to allow patients to be gently turned onto their side
Fast deflation through Rapid Release CPR valve
Intuitive touch screen display allows easy control of mattress functions
Static mode provides firm and stable surface for essential nursing procedures such as physiotherapy, wound dressing and changing bed linen
Static mode automatically reverts to Alternating Mode after 120 minutes
Maximum Inflate mode quickly produces a firm surface for nursing procedures or for bed exits or transfers to chair or trolley
Transport mode facilitates bed movement without patient risk
Audible and visual alarm provides peace of mind for nursing staff
Cable management system ensures power cable is safely and securely retained off the floor
V-Lock system prevents the power cord from being accidently unplugged
Control panel automatically locks out after 2 minutes of inactivity
Clearly marked foot end to aid correct positioning of patient

Mircoclimate Control

The optimised moisture vapour transmission rate of the Dartex® cover allows control of the microclimate
Reduction of both temperature and moisture at the skin/mattress interface decreases the risk of pressure injury as well as enhancing patient comfort

Improved Infection Control

Waterproof Dartex® cover with high frequency welded seams prevent the ingress of fluid into the mattress
Cover contains an antimicrobial agent that can withstand high temperature washing
Smooth covers reduce shear and friction and allow for easy wipe down with disinfectant
360° zip ensures cover can be easily removed for infection control of cells and laundering
Generous waterfall flap protects the zip and the integrity of the air-cells

Technical Specification
Mattress material Cells: Polyurethane
Cover: Two-way stretch Polyurethane coated Nylon
Classification Class B Medical Device / Class II
Mattress – flammability rating Complies with BS7175 ignition source 0, 1 and 5
Power unit – flammability rating / ingress protection UL 94 V-0 / IP 42
Power supply / power consumption: 230 V~ ±10%, 50 / 60 Hz 20 W max
Dimensions
Mattress sizes 2000 x 900 x 200 mm
(Reduced Height)
Max. patient weight 250 kg
Pump unit dimensions 400 x 160 x 250 mm
Mattress weight 11 kg
Pump weight 6.8 kg